Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
products
BIT Isolierschlauch

Schrumpf- und Isolierschlauch mit UL-Zulassung

UL-zertifizierte Schrumpf- und Isolierschläuche

Für viele unserer Schrumpf- und Isolierschläuche bestätigen wir eine Zulassung nach UL 224.

Folgende Schläuche fallen unter das UL-Listing YDPU2.E196690 :

Cat.

No.

Max V

rms

Max Oper

Temp, °C

Color

Recognized

Oil-resistance

Class[a]

VW-1

Rated[b]

 

Not heat shrinkable Polyvinyl Chloride (PVC) tubing / PVC Isolierschlauch

BIS 105 UL 600 105 Black or Clear None Yes
 

Not heat shrinkable Silicone / Silikon Isolierschlauch

BIS SI UL 600 150 All except clear & black None Yes (ID size 6.5-25 mm only)
BIS SI UL (Black) 600 150 BK None Yes
 

Flexible heat shrinkable polyolefin tubing / Polyolefin Schrumpfschlauch

BP 125, BP 300, BP 135, BPIMS 300, BPIMS-LF, BPUTW, BP 135 GE/GR, BP 135 VW1
600 125 All except clear None Yes
BP 125, BP 300, BP 135, BPIMS 300, BPIMS-LF, BPUTW, BP 135 GE/GR, BP 135 VW1, BP 400
300 125 All except clear None Yes
 

Flexible heat shrinkable polyolefin tubing with liner / Polyolefin Schrumpfschlauch mit Kleber

BPBK 600 125 Black None Yes
BPDW 100 % 600 125 All except clear None Yes
BPDW 102 % 600 125 All except clear None Yes
BPDW 104 % 600 125 All except clear None Yes
BPDW HT % 600 125 All except clear None Yes
 

Flexible heat shrinkable modified Fluoropolymer tubing / Fluorpolymer Schrumpfschlauch

BPVDF 600 150 Clear None Yes
BPVDF 150 600 150 All including Clear None Yes
BPVDF 175 600 150 All including Clear None Yes
 

Not heat shrinkable Polytetrafluoroethylene (PTFE) tubing / PTFE Isolierschlauch

PTFE 150 150 200 All including clear None Yes
PTFE 300 300 200 All including clear None Yes
PTFE 600 600 200 All including clear None Yes

 

[a] – Tubing is considered to comply with the optional Oil Resistance requirements only if authorized in the above table and marked „Oil Resis-tant“ (or „Oil Res“), followed by the class (01, 02 or 03).

[b] – Tubing is considered to comply with the optionalVW-1 flammability requirements only if authorized in the above table and if so marked.

Marking: Company name, catalog designation, inside diameter (before and after recovery for heat-shrinkable tubing), voltage rating, tempe-rature rating in degrees Celsius and date of manufacture (or traceable code) printed on tags attached to both ends of the tubing or printed on the shipping spool label or smallest unit container in which the product is packaged.

UL 94

Bei dem Standard UL 94 wird zwischen UL 94 HB (horizontale Brennprüfung) und UL 94 VB (vertikale Brennprüfung) unterschieden. HB bedeutet hierbei, dass der Prüfkörper für den Entflammbarkeitstest horizontal eingespannt wird.

Bei der vertikalen Brennprüfung wird der Probekörper am oberen Ende eingespannt und am unteren Ende zweimal für 10 Sekunden beflammt. Hierbei ergeben sich die Einteilungen in folgende Klassen:

Klasse max. Nachbrennzeit beider Beflammungen zusammen max. Nachbrennzeit aller Muster und Beflammungen max. Nachglühzeit Abtropfen von brennendem Material
UL 94 V-0 10 50 30 nicht zulässig
UL 94 V-1 30 250 60 nicht zulässig
UL 94 V-2 30 250 60 zulässig

 

 

 

 

 

 

Viele unserer Schläuche, Kabelbinder und andere Produkte sind aus Kunststoffen produziert, für die es eine Einstufung nach UL 94 gibt.

Sprechen Sie uns hierzu gerne an.

Übersicht Schrumpfschläuche


    * Diese Angaben sind Pflichtangaben.

    Zurück nach oben